Proportional flow control valve
                                                                                     Proportional flow control valve


            PERFORMANCE SPECIFICATIONS
            Oil viscosity u = 30 mm /s
                             2
             Q = f (I)  Volume flow signal characteristics        Q = f (p)  Volume flow pressure characteristics
                 Q [l/min]                                           Q [l/min]
              100  K0978                                           100  K0979
                                                     Q  = 80 l/min
               80                                     N             80                                   Q = 80 l/min
                                                     Q  = 63 l/min                                        N
                                                      N
               60                                                   60                                   Q  = 63 l/min
                                                                                                          N
               40                                    Q N  = 32 l/min  40
                                                                                                         Q  = 32 l/min
               20                                                   20                                    N
                0                                                    0
                  0   10  20  30  40 50 60 70 80 90  100 I  [%]        0   50  100  150  200  250  300  350 p [bar]


             Q  = f (p)  Leakage volume flow characteristics
              L
                 Q [cm /min]
                     3
              400  K0980
              300

              200
              100
                0
                  0   50   100  150  200  250  300  350 p [bar]








            ACCESSORIES                                          SURFACE TREATMENT
             Proportional amplifier          Register 1.13        ◆  The cartridge body is gas-nitro-carburised
                                                                  ◆  The armature tube and the slip-on coil are zinc- / nickel-coated
             Electric plug B (black)         Article no. 219.2002
             Technical explanations          Data sheet 1.0-100
             Filtration                      Data sheet 1.0-50
                                                                 SEALING MATERIAL
                                                                 NBR or FKM (Viton) as standard, choice in the type code





            INSTALLATION NOTES                                   STANDARDS

             Mounting type      Screw-in cartridge 1  ⁄16 “-12 UN  Cartridge cavity   ISO 7789
                                               5
             Mounting position  Any, preferably horizontal        Solenoids           DIN VDE 0580
             Tightening torque  M  = 80 Nm Screw-in cartridge     Connection execution D  EN 175301 – 803
                                 D
                                M  = 5 Nm knurled nut             Protection class    EN 60 529
                                 D
                                M  = 9,5 Nm HB0                   Contamination efficiency  ISO 4406
                                 D
                                M  = 5,5 Nm HB4,5
                                 D











                               www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 22 16  2.6-675 E