Page 1382 - Softbound_Edition_19_en
P. 1382
Module type manifold blocks Module type manifold systems
Module typ manifold system
DIMENSIONS HYDRAULIC CONNECTION Module type manifold blocks
• p = 350 bar ®
20.5 max nG4-Mini
10 G1/8" 2 2x 8.5 8 A P B
G 1/8" P T A B M4 T T 0 11 21
T
B A 34
P 16 10 description function application
P T 20 Module type manifold blocks with interface The module type manifold blocks are available This block system can be used as a replace-
30 12 NG4-Mini according to Wandfluh standard. The with 3 different basic circuits, namely parallel, ment for expensive special blocks. Existing
38 drilling pattern is identical with NG3-Mini. This serial and pressure reduction circuit. An inter- systems may be exended or reduced by adding
50 50 allows direct combination with the NG4-Mini mediate block serves as spacer where as removing modular blocks.
required.
module type manifold blocks. Using an adapter
27 plate and connecting blocks, combinations with
NG6 and NG10 are also possible (see also data
sheet 2.9-80). The module type manifold blocks
are made from steel and are phos-phated.
PARTS LIST
Position Article Description
36
25 24 10 160.2155 O-ring ID 15,54 x 2,62 (NBR)
15 type code
160.6155 O-ring ID 15,54 x 2,62 (FKM) B LV 4 #
8 Mounting interface acc. to Wandfluh standard
56
Module type manifold
64 Nominal size 4-Mini
Type list
ACCESSORIES STANDARDS Parallel circuit P
S
Serial circuit
Module type manifold Data sheet 2.9-80 Mounting interface Wandfluh standard Pressure reduction circuit D
Intermediate block Z
Fastening Data sheet 2.9-122
Design-Index (Subject to change)
General specifications Hydraulic specifications
Description Parallel-, serial- and pressure reduction Working pressure p max = 350 bar
circuit, intermediate block
SEALING MATERIAL INSTALLATION NOTES Nominal size NG4-Mini acc. to Wandfluh standard
NBR or FKM (Viton) as standard, choice in the type code Mounting type Fixing bracket and fixing screws Fastening see data sheet 2.9-122
Threaded connections A, B, P, T G1/4”
Connection
(see data sheet 2.9-122) Mounting position any
Mounting position Any Weight: BLV4P, S, D m = 0,9 kg
BLV4Z m = 0,3 kg
syMBols
Block for parallel circuit Block for serial circuit Block for pressure reduction circuit Intermediate block
BLV4P BLV4S BLV4D BLV4Z
P P T1 P Pred P
T T T T T T
A B A B A B
Ø 20.5 G 1/4“ 9.5
31.5 G 1/4“ Ø 8.5
P T 2
10
Wandfluh AG Postfach CH-3714 Frutigen T A B
Tel. +41 33 672 72 72 Fax +41 33 672 72 12 sales@wandfluh.com M5
B A
14
27
Wandfluh AG Tel. +41 33 672 72 72 E-mail: sales@wandfluh.com Illustrations not obligatory 44 Data sheet no.
www.wandfluh.com Illustrations are not binding Data subject to change 2/2 Edition: 19 47 2.9-85 E Postfach Fax +41 33 672 72 12 P Internet: www.wandfluh.com 21 Data subject to change 2.9-90E 1/2
21
CH-3714 Frutigen Edition 03 26
Page 1382
P T
64 12
38
50
T1 T
T A B
B A
P
P T
Pred T
T A B
B A
P
P T
12
64 50
50
27
36
25 24
15
8
56