Proportional flow control valve
                                                                                     Proportional flow control valve


            ACTUATION                                            HYDRAULIC SPECIFICATIONS
             Actuation          Proportional solenoid, wet pin push   Working pressure  p  = 350 bar
                                                                                     max
                                type, pressure tight              Maximum volume flow  Q  = 70 l/min
                                                                                      max
             Execution          MKY45 / 18x60 (data sheet 1.1-183)  Volume flow direction  1 → 2
                                MKU45 / 18x60 (data sheet 1.1-184)  Leakage oil      See characteristics
             Connection         Cable gland for cable Ø 6,5…14 mm  Nominal volume flow   Q  = 55 l/min
                                                                                      N
            Attention!  The UL execution is always supplied without cable   range
                     gland                                        Hysteresis         ≤ 8 % at optimal dither signal
                                                                  Repeatability      ≤ 3 % at optimal dither signal
                                                                  Fluid              Mineral oil, other fluid on request
                                                                                                  2
                                                                                         2
            PERFORMANCE SPECIFICATIONS                            Viscosity range    12 mm /s…320 mm /s
            Oil viscosity u = 30 mm /s                            Temperature range   Operation as T4
                             2
                                                                  fluid              NBR -25…+70 °C (L15 / L17)
             Q = f (I)  Volume flow signal characteristics                           FKM -20…+70 °C (L15 / L17)
                Q [l/min]                                         Contamination      Class 18 / 16 / 13
               60  K4154                            Q N  = 55 l/min  efficiency
               50                                                 Filtration         Required filtration grade ß 6…10 ≥ 75,
               40                                                                    see data sheet 1.0-50
               30
               20
               10
                0
                 0   10  20  30  40 50 60 70 80 90  100 I [%]


             Q = f (p)  Volume flow pressure characteristics      Q  = f (p)  Leakage volume flow characteristics
                                                                   L
                Q [l/min]                                            Q [cm /min]
                                                                         3
               70  K4155                                           400  K0980
               60
               50                                                  300
               40                                                  200
               30
               20                                                  100
               10
                0
                 0    50  100  150  200  250  300  350 p [bar]        0    50  100  150  200  250  300  350 p [bar]

            Note!    With the L15 / L17 execution for ambient temperatures
                     up to 70 °C, the  performance specifications have been
                     evaluated with an ambient temperature of 50 °C

            DIMENSIONS                                           HYDRAULIC CONNECTION
                                                                 Cavity drawing according to ISO 7789–33–01–0–98

                    110                                                               M33 x 2
                                                s36
                   71                             M33x2
                94                                  (2)                                        (2)

                                                           (1)
                   23
                                                                                               (1)
                15     12  17   18    10    18    40   30  60                            (1)
             MD=5.5Nm  MD= 9Nm
                                     60
                                     100             51          Note!    For detailed cavity drawing and cavity tools see data
                                         157                              sheet 2.13-1005




                               www.wandfluh.com  Illustrations are not binding  Data subject to change  3/4  Edition: 21 21  2.6-655 E