Proportional throttle valve Proportional throttle valve
Proportional throttle valve
SYMBOL CERTIFICATES PERFORMANCE SPECIFICATIONS
„normally closed” DN „normally open” DO Surface Mining Standard M248 Oil viscosity u = 30 mm /s
2
2 2 -25 °C Electronic Q = f (I) Volume flow adjustment characteristics DN Q = f (I) Volume flow adjustment characteristics DO
to… ∆p = 20 bar ∆p = 20 bar
ATEX x x x x Q [l/min] Q [l/min]
1 1 IECEx x x x x 35 K1185 Q = 25 l/min 35 K1184
N
CCC x x x x 30 30 Q = 25 l/min
N
25
25
EAC x x x x 20 20 Q = 10 l/min
N
15 = 10 l/min 15
Australia x x x 10 Q N 10
Q = 6,3 l/min
MA x x x 5 N 5 Q N = 6,3 l/min
UL / CSA x x 0 0 10 20 30 40 50 60 70 80 90 100 l [%] 0 0 10 20 30 40 50 60 70 80 90 100 l [%]
The certificates can be found on www.wandfluh.com
GENERAL SPECIFICATIONS ACTUATION Q = f (p) Volume flow pressure characteristics DN Q = f (p) Volume flow pressure characteristics DO
I = I I = 0 mA
Designation Proportional throttle valve Actuation Proportional solenoid, wet pin push G
Construction Direct operated type, pressure tight 45 Q [l/min] 45 Q [l/min]
K1186
K1187
Mounting Screw-in cartridge construction Execution MKY45 / 18x60 (data sheet 1.1-183) 40 40
N
Nominal size M22 x 1,5 according to ISO 7789 MKU45 / 18x60 (data sheet 1.1-184) 35 Q = 10 l/min 35 Q = 25 l/min
30
30
Q = 25 l/min
N
N
Actuation Ex-protection proportional solenoid Connection Cable gland for cable Ø 6,5…14 mm 25 Q = 6,3 l/min 25 Q = 10 l/min
N
20
N
20
N
Ambient temperature Operation as T6 Attention! The UL execution is always supplied without cable 15 15 Q = 6,3 l/min
10
10
-25…+40 °C (L9) gland 5 5
Operation as T4 0 0 350 p [bar]
-25…+90 °C (L9) 0 50 100 150 200 250 300 350 p [bar] 0 50 100 150 200 250 300
-25…+70 °C (L15 / L17)
Weight 1,95 kg ∆p = f (Q) Pressure drop volume flow characteristic DN ∆p = f (Q) Pressure drop volume flow characteristic DO
MTTFd 150 years I = I I = 0 mA
G
p [bar] p [bar]
N
N
N
N
40 K1188 Q = 6,3 l/min Q = 10 l/min 50 K1164 Q = 6,3 l/min Q = 10/min
30 40
30
20 Q = 25 l/min Q = 25 l/min
N
N
HYDRAULIC SPECIFICATIONS ELECTRICAL SPECIFICATIONS 20
10
Working pressure p = 350 bar Protection class IP65 / 66 / 67 10
max
Maximum volume flow Q = 45 l/min Relative duty factor 100 % DF 0 0
max 0 5 10 15 20 25 30 35 Q [l/min] 0 5 10 15 20 25 30 35 Q [l/min]
Volume flow direction 1 → 2 Voltage tolerance ± 10 % with regard to nominal voltage
Leakage oil On request Standard nominal 12 VDC, 24 VDC
Nominal volume flow Q = 6,3; 10; 25 l/min voltage
N
range at 10 bar valve pressure drop Limiting current at… °C L9, 40 °C ACCESSORIES MANUAL OVERRIDE
Hysteresis ≤ 8 % at optimal dither signal I = 625 mA (12 VDC) Proportional amplifier Register 1.13 HB4,5 as standard
G
Fluid Mineral oil, other fluid on request I = 305 mA (24 VDC) Flange body / sandwich plate NG4-Mini Data sheet 2.6-720
G
Viscosity range 12 mm /s…320 mm /s L15 / 17, 50 °C Flange body / sandwich plate NG6 Data sheet 2.6-740
2
2
Temperature range Operation as T6 I = 950 mA (12 VDC) Threaded body Data sheet 2.9-205 SEALING MATERIAL
G
fluid NBR -25…+40 °C (L9) I = 450 mA (24 VDC) Technical explanations Data sheet 1.0-100 NBR or FKM (Viton) as standard, choice in the type code
G
FKM -20…+40 °C (L9) L15 / 17, 70 °C
Operation as T4 I = 910 mA (12 VDC) Filtration Data sheet 1.0-50
G
NBR -25…+70 °C (L9 or L15 / L17) I = 420 mA (24 VDC)
G
FKM -20…+70 °C (L15 / L17) Standard nominal 9 W, 15 W, 17 W
FKM -20…+70 °C (L9) power
Contamination Class 18 / 16 / 13 Temperature class Nominal power 9 W: T1…T6
efficiency Nominal power 15 W / 17 W: T1…T4
Filtration Required filtration grade ß 6…10 ≥ 75, Note! Other electrical specifications see data sheet 1.1-183
see data sheet 1.0-50 and 1.1-184